4. Operation
MotionOrb™ User Manual Rev. 1 Page 25 of 96
Setting The MS
Mode
To set the MS Mode and MS Address, do the following:
1. Press <MENU> until MS shows in the display.
2. Press <ENTER> until MS Mode shows on the top line of the display.
3. Use <UP> or <DOWN> until the desired MS mode (13) shows on the bottom line of the
display.
4. Press <ENTER>. MS Address shows in the display.
5. Use <UP> or <DOWN> until the desired MS Address (13) shows on the bottom line of the
display.
6. Press <ENTER>. MS shows in the display.
The grouping of the MS mode for DMX only works if all the MotionOrb™ products are
set to the same DMX address.
The MS Mode and MS Address grouping options are not available in any of the DMX
pixel mapping modes.