Scorpion™ Storm MG User Manual Rev. 7 14 06/14/2013
General Troubleshooting
Symptom Solution(s)
Lights
& Snow Controllers
& Chaser
Check fan thermal switch reset
Beam is very dim or
not bright
Clean optical system or replace lamp
Check 220/110v switch for proper setting
ü
Breaker/Fuse keeps
blowing
Check total load placed on device
ü
Check users manual for speed adjustment
Check for power on Mains.
Check device’s fuse. (internal and/or external)
ü
ü ü
there is no
movement to the
Make sure you have the correct audio mode on the
control switches. If audio provided via ¼” jack, make
sure a live audio signal exists
Adjust sound sensitivity knob
ü
ü ü
Lamps cuts off
sporadically
Possible bad lamp or product is overheating.
Lamp may be at end of its life.
ü
on after power failure
Some discharge lamps require a cooling off period
before the electronics in the product can kick start it
again, wait 5 to 10 minutes before powering up
ü
Install terminator
Note: Keep DMX cables separated from power cables
ü ü ü ü
Check 220/110v switch for proper setting
Re-install bulb, may have shifted in shipping
Bounce mirror motor may have shifted during shipping,
readjust
ü
Check slip ring & brushes for contact
Install bulb
ü
Check reset switch
Check cable connections
ü
Make sure connector is firmly connected to device
ü ü
All Chauvet lighting products featuring standalone
functions do not require additional settings, simply
power the product and it will automatically enter into
this mode
ü
If you still have a problem after trying the above solutions, please contact CHAUVET Technical Support.
Technical Support
Address: Service Dept.
5200 NW 108
th
Avenue, Sunrise, FL 33351 (U.S.A.)
Support (Email): tech@chauvetlighting.com
Telephone: (954) 577-4455 - (Press 4)