SlimPAR Pro VW User Manual 10 Rev. 3
4. OPERATING INSTRUCTIONS
Configuring the Starting Address
fixture uses 7 DMX channels in its maximum setting. In this DMX
configuration/personality, the highest channel that the fixture may be set to in order to function
properly is 506. Any address higher than this will prevent access to all of the channels, while in this
mode; however, if you desire to use one of the other DMX channels configurations (personalities),
please consider the total DMX channels when selecting a DMX address.
Access control panel functions using the four buttons located directly underneath the LED display
on the included wired remote.
<MENU>
Used to scroll through the
current operating mode,
as well as back out of the
current menu option
<ENTER>
the right in the menu map
and select a value and
<UP>
Used to select increasing
advancement in the value
<DOWN>
Used to select decreasing
advancement in the value
The Control Panel shows the current state of the unit. It is used to select the operating
mode, as well as the sub-features. For a detailed layout of the control panel functions,
please see the “menu map” section.
DMX starting address selection
Personality PERS
3-channel operating mode: warm/cool white color
temperature mixing with dimmer
2-channel operating mode: warm/cool white color
temperature mixing
Dimming Curve dIM
Color
Temperature
Preset
C--
Custom Static
Color
U--
Combine warm and cool white to create a custom, static
color temperature mix
Strobe speed (
=no strobe)
Auto Program P--
There is no strobing in the following modes:
and
. For full function control, use 7-
Channel DMX mode.